Tracheal Intubation with Aura-i and aScope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway

Pavoni, Vittorio and Froio, Valentina and Nella, Alessandra and Simonelli, Martina and Gianesello, Lara and Horton, Andrew and Malino, Luca and Micaglio, Massimo (2015) Tracheal Intubation with Aura-i and aScope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway. Case Reports in Anesthesiology, 2015. pp. 1-4. ISSN 2090-6382

[thumbnail of 453547.pdf] Text
453547.pdf - Published Version

Download (1MB)

Abstract

The supraglottic airway’s usefulness as a dedicated airway is the subject of continuing development. We report the case of an obese patient with unpredicted difficult airway management in which a new “continuous ventilation technique” was used with the Aura-i laryngeal mask and the aScope-2 devices. The aScope-2/Aura-i system implemented airway devices for the management of predictable/unpredictable difficult airway. The original technique required the disconnection of the mount catheter from Aura-i, the introduction of the aScope-2 into the laryngeal mask used as a conduit for video assisted intubation and then towards the trachea, followed by a railroading of the tracheal tube over the aScope-2. This variation in the technique guarantees mechanical ventilation during the entire procedure and could prevent the risk of hypoventilation and/or hypoxia.

Item Type: Article
Subjects: Eurolib Press > Medical Science
Depositing User: Managing Editor
Date Deposited: 18 Feb 2023 11:41
Last Modified: 13 Mar 2024 04:16
URI: http://info.submit4journal.com/id/eprint/957